We use cookies to enhance your experience. By continuing to browse this site you agree to our use of cookies. More info.
What is magnetic particle tracking, and what are the latest developments related to this technology? This article considers principles, limitations, and recent applications.
Image Credit: Gorodenkoff/Shutterstock.com
MPT is a recently developed technology that can measure the translation and rotation motion of a particle in an opaque environment. This technique has potential applications in studying the accurate position and three-dimensional (3D) orientation of organs in the human body, such as in capsule endoscopes.
Using this technique, the organs can be functionally examined without any radiation exposure. In pharmaceutical research, this method offers a great opportunity to study remote drug release at any position of the gut. In addition, MPT also has significant applications in diagnostics, imaging, targeting, and therapy owing to its suitable magnetic properties and biocompatibility.
The MPT technique tracks the magnetic field of a single magnetic tracer, which is measured using anisotropic magnetic resonance (AMR) sensors, and detects the translation and rotation motion of the particle in a completely 3D cylindrical fluidized bed. In MPT, a magnetic source is located according to its field, which is modeled as a dipole; MPT uses a single tracer particle that has a dipole. This allows for the detection of the particle position and orientation.
MPT overcomes the challenges in studying collision detection for particles of arbitrary shape and size. In this technique, magnetic markers are monitored by employing a specially designed permanent magnet aligned by a vertically oriented pulsed magnetic field. This alignment allows monitoring of marker position from the stray field components.
Researchers have monitored marker position as a 3D plot in real-time. The method provides a spatial resolution of better than 10 mm and a temporal resolution of about 1 s, and thus can distinguish between adjacent loops of the gut. This allows for viewing tracers in cells (cell tracking), blood (perfusion), and other functional systems such as drug targeting and drug delivery systems within a living organism. It also offers a wide range of applications in the field of engineering, physics, chemistry, medicine, mathematics, and computer science.
MPT has multiple advantages - it is a safe technique and does not involve any radioactive material or X-rays. It is a highly sensitive method in granular dynamics as it provides translation and rotational information of a particle, which is difficult to obtain using other techniques. It offers high temporal resolution to measure high-speed flow, and it is cost-effective as the magnetometers and sensors are less expensive in comparison to the equipment used in non-optical approaches.
More from AZoM: Calculating the Polydispersity Index of a Polymer
The accuracy and precision of this method lie in the reconstruction of the position and orientation of a magnetic dipole. Thus, the reconstruction process of MPT using typical optimization approaches limits its applications as it is highly time-consuming. In addition, the magnetic field decays rapidly. This is inversely proportional to the cubic of the distance, and so the tracking range is limited.
Existing analytical reconstruction algorithms have certain limitations, and they usually depend on the gradient of the magnetic field. This is often not easy to measure accurately in different applications. Researchers from the University of Kansas, writing in the journal Plos One, recently developed and examined new MPT reconstruction algorithms and compared the results with an optimization approach.
The researchers have developed a semi-analytical solution and the related reconstruction algorithm. To reduce the measurement uncertainty in practical applications, deep neural network (DNN)-based models have also been developed to denoise the reconstructed trajectory. These are more accurate in position reconstruction.
Recent approaches have combined the traditional wavelet model with DNN, which provides a more accurate velocity reconstruction and performs well in the orientation reconstruction. Further, to improve the reconstruction accuracy, convolutional neural networks (CNN), gated recurrent units (GRU), and Wavelet transform (WT)-based methods were combined to denoise the position, velocity, and orientation signals. All these methods improved the reconstruction accuracy.
The extended Kalman filter (EKF) algorithm has an accuracy of the same amount as the optimization method, however it is orders of magnitude faster. This is explored in the journal AIP. The accuracy of the position obtained using EKF is about 0.6%, whilst the uncertainty of orientation is less than 1.5°. MPT was applied in order to measure a dense granular shear flow, and this was used to investigate the spatial distribution of a tracer particle.
MPT is one of the most promising imaging technologies to emerge in the last two decades, and is expected to change the landscape of modern medical imaging and in vivo translational research. Magnetic particle imaging (MPI) is an emerging radiation-free imaging modality that utilizes sensitive, safe, and biocompatible superparamagnetic iron oxide nanoparticles (SPIONs) as its tracing material. With multiple promising approaches for clinical translation and sustained research in biomedical applications, MPT will be a crucial, complementary clinical diagnostic and therapeutic tool in the near future.
Buist KA, Jayaprakash P, Kuipers JAM, Deen NG, Padding JT. Magnetic particle tracking for nonspherical particles in a cylindrical fluidized bed. AIChE J. 2017;63(12):5335-5342. https://pubmed.ncbi.nlm.nih.gov/29213144/
Tao X, Tu X, Wu H. A new development in magnetic particle tracking technology and its application in a sheared dense granular flow. Rev Sci Instrum. 2019 Jun;90(6):065116. https://pubmed.ncbi.nlm.nih.gov/31255032/
Huixuan Wu, Pan Du, Rohan Kokate, Jian-Xun Wang. A semi-analytical solution and AI-based reconstruction algorithms for magnetic particle tracking. PloS July, 2021. https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0254051
Disclaimer: The views expressed here are those of the author expressed in their private capacity and do not necessarily represent the views of AZoM.com Limited T/A AZoNetwork the owner and operator of this website. This disclaimer forms part of the Terms and conditions of use of this website.
Please use one of the following formats to cite this article in your essay, paper or report:
Cheriyedath, Susha. (2022, April 11). Novel Clinical Uses of Magnetic Particle Tracking. AZoM. Retrieved on May 14, 2022 from https://www.azom.com/article.aspx?ArticleID=21570.
Cheriyedath, Susha. "Novel Clinical Uses of Magnetic Particle Tracking". AZoM. 14 May 2022. <https://www.azom.com/article.aspx?ArticleID=21570>.
Cheriyedath, Susha. "Novel Clinical Uses of Magnetic Particle Tracking". AZoM. https://www.azom.com/article.aspx?ArticleID=21570. (accessed May 14, 2022).
Cheriyedath, Susha. 2022. Novel Clinical Uses of Magnetic Particle Tracking. AZoM, viewed 14 May 2022, https://www.azom.com/article.aspx?ArticleID=21570.
Do you have a review, update or anything you would like to add to this article?
AZoM speaks with Dr. Nicola Ferralis from MIT about his research that has developed a low-cost process of creating carbon fibers from hydrocarbon pitch. This research could lead to the large-scale use of carbon fiber composites in industries that have thus far been limited.
In this interview, AZoM speaks with Marco Enger, Senior Tribologist from GGB, to discuss how nano fillers affect transfer films within tribological systems.
Ahead of their talk on green chemistry and profitability in laboratory research at ChemUK 2022, AZoM spoke with Jacqueline Balian from Gambica and Martyn Fordman from Asynt about encouraging sustainability in the chemical industry.
COXEM's CP-8000+ is a powerful cross section polishing tool that uses an argon ion beam to allow precise, advanced sample preparation. Its state-of-the-art technology means the sample is not deformed and does not suffer any kind of physical damage.
This product profile outlines the Evolution™ Pro UV-Vis Spectrophotometers from Thermo Fisher Scientific.
Extrel’s all-new MAX300-RTG 2.0 is the real-time industrial gas analyzer now redesigned with a touch screen.
This article provides an end-of-life assessment of lithium-ion batteries, focusing on the recycling of an ever-growing amount of spent Li-Ion batteries in order to work toward a sustainable and circular approach to battery use and reuse.
Corrosion is the degradation of an alloy caused by its exposure to the environment. Corrosion deterioration of metallic alloys exposed to the atmosphere or other adverse conditions is prevented using a variety of techniques.
Due to the ever-increasing demand for energy, the demand for nuclear fuel has also increased, which has further created a significant increase in the requirement for post-irradiation examination (PIE) techniques.
AZoM.com - An AZoNetwork Site
Owned and operated by AZoNetwork, © 2000-2022